Heliocol Logo
 
Residential Pools > Easy > Technical Information

HELIOCOL Unique Technical Features

  • Patented Individual Tube Design allows for expansion and contraction, eliminating cracks and leaks.
  • One piece "over-molded" construction eliminates welds.
  • No moisture build-up under collectors.
  • Innovative mounting hardware eliminates need for radiator hoses, metal clamps and multiple straps across the collectors.
  • Designed to withstand hurricane force winds.
  • Low collector head loss rate reduces pump requirements.

 

Certification Data

  • Ortech International Laboratories
  • Solar Rating and Certification Corporation (SRCC)
  • Solar Energy Analysis Laboratory (SEAL)
  • DSET Laboratories, Inc.
  • HRS, Florida (Required for Commerical Use)
  • British National Water Council (for potability)
  • German Federal Health Board
  • Israeli Technical Institute
  • Standard Installation Corporation of Israel IAPMO ISO 9002 Certification
  • Dade County, Florida
  • Miami Testing Laboratory (MTL)
  • Florida Solar Energy Center (FSEC)
  • City of Los Angeles

 

Collector Data

Collector Model
HC-50
HC-40
HC-30
HC-12.5
HC-10
Size, Nominal
4'x12.5'
4'x10.5'
4'x8'
1'x12.5'
1'x10.5'
Width
47" / 120cm
47" / 120cm
47" / 120cm
11.75"
11.75"
Length
152.1" / 380cm
127" / 323cm
91" / 231cm
151.5"
127"
Area (sq. ft.)
50.0 / 4.65m^2
41.6 / 3.88m^2
30.0 / 2.77m^2
12.2
10.2
Manifold Diameter
2" / 5.08cm
2" / 5.08cm
2" / 5.08cm
2"
2"
Weight, Dry
22lbs / 10kg
19lbs / 8.5kg
15lbs / 6.8kg
5.5lbs
4.75lbs
Volume Capacity
3.7gal / 14L
3.1gal / 12L
2.4gal / 9L
.93gal
.78gal
Working Pressure
90 PSI
90 PSI
90 PSI
90 PSI
90 PSI
Burst Pressure
270 PSI
270 PSI
270 PSI
270 PSI
270 PSI
Recommended Flow
5 GPM
4 GPM
4 GPM
1.25 GPM
1 GPM

 

Performance Rating

Collector Size
Int'l Standard
ORTECH
National
SRCC
Florida Standard
FSEC Data
HC-50
4'x12.5'
47,400
47,400
45,000
HC-40
4'x10.5'
39,400
39,400
37,440
HC-30
4'x8'
28,440
28,440
27,000
Performance Equations
.872 - 3.729 (Ti - TA) / I
KAX = 1.00 - .0316(S) - .0104(S)2
.825 - 3.74 (Ti-TA)/I
KAX=1.00-0.4(S)


Performance Note:
Solar Scientists agree that there are many variables to consider when properly sizing a system. Wind conditions, micro climates, flow rates, orientation and shading of the pool and/or collectors all effect the performance of your system. A BTU rating is just one of the many factors to condiers.

 

Head Loss Per Flow Rate

flow rate chart

 

How Solar Pool Heating Works

A) Using your existing pool pump, pool water is directed through a series of valves to your solar collectors.

B) Pool water enter the solar collectors at the bottom and rises to the top through the individual tubes of the collector.

C) As the water rises through the collector it is heated by the sun's radiant energy.

D) The water is then returned to your pool to repeat the cycle untill your pool has been warmed by the sun.

how it works